banner
Products
Classy appearance
Ce Certificate Aio-10b Medical Syringe Infusion Pump with Good Quality

Ce Certificate Aio-10b Medical Syringe Infusion Pump with Good Quality

Basic Parameter Specification Special Function 1. Keep-Vein-Open (KVO): After finishing predetermined infusion volume, t;
Basic Info
Model NO. AIO-10B
Waterproof Level Ipx4
Electric Shock Protection Class I, Type CF
Battery Continuous Use Time About 6 Hours
Syringe Flow Rate Precision Less Than or More Than 3%
Transport Package Carton
Specification CE ISO
Trademark healicom
Origin Jiangsu, China
HS Code 8413190000
Production Capacity 2000 Units Per Month
Product Description

Ce Certificate Aio-10b Medical Syringe Infusion Pump with Good Quality


Basic Parameter
Item
Model
AIO-10BAIO-10C
Dimensions(mm)354(L)×132(W)×199(H)354(L)×132(W)×268(H)
Weight2.7kg3.6kg
Battery Continuous Use TimeAbout 6 hours
(fully charged new battery running with rate 5ml/h)
About 5 hours
(fully charged new battery running with rate 5ml/h)
Rated Consumption≤25 VA≤35 VA

Specification
Power SupplyAC 100V~AC 242V,50/60HZ
Built-in BatteriesDC 12V 1800mAh, Ni-MH, rechargeable
Infusion Flow Selection0.1ml/h~1200ml/h (1-150d/min), original value is 0.1ml/h (1d/min)
Syringe Flow Selection0.1ml/h~1600ml/h, original value is 0.1ml/h
Syringe Size5/6ml, 10/12ml, 20/25ml, 30/35ml,50/60ml
Bolus RateSyringe 50ml:1600ml/h
Syringe 30ml:900 ml/h
Syringe 20ml:600 ml/h
Syringe 10ml:400 ml/h
Syringe 5ml: 200ml/h
Infusion Range0.1ml~9999.9ml, original value is 0.1ml
Infusion Precisionvolume mode ±5%, drop mode ±2d
Syringe Flow Rate Precision±3%
KVO0.1~5ml/h
Occlusion PressureHigh:110kPa±20kPa (825mmHg±150 mmHg)
Middle:80kPa±30kPa(600mmHg±225mmHg)
Low:60kPa±20kPa(450mmHg±150 mmHg)
The biggest output pressure:< 975mmHg(130kPa)
Use EnvironmentTemperature: 5ºC~43ºC
Relative Humidity:≤90%RH (Under without condensation status)
Atmospheric Pressure:860hPa~1060hPa
Storage EnvironmentTemperature:-20ºC~+55ºC
Relative Humidity:≤90%RH (Under without condensation status)
Atmospheric Pressure:860hPa~1060hPa
Waterproof LevelIPX4
Electric Shock ProtectionClass I, Type CF
Alarm:occlusion, nearly finish, finish, standby (no operation), door open, low battery, battery exhausted etc.
Functionpower indicator, transfusion amount display, flow rate display, infused volume display etc.

Special Function
1. Keep-Vein-Open (KVO): After finishing predetermined infusion volume, to prevent the formation of thrombus, continue infusion with preset minimum rate 0.1-5ml/h(setted).

2. Power Supply Switching Function: When the AC power supply is off, it will automatically switch to internal battery power supply and prompt at the same time. When AC is switched on, it is automatically converted back to AC supply.

3. Repeat Alarm Function: After the operator presses the "" key, if the reason causing the alarm has be untreated for about 2 minutes, the alarm will sound again to alert the operator to solve the problem.

4. Data Memory Function: Save the last setting of sound volume level, brand and occlusion pressure level, to prepare for the next use. The longest memory time is 5 years.

5. Light: For convenience, when installing or removing IV line at night or in darkness, light will automatically turn on after the door is open. The light is an LED light source (white).

6. Battery Protection Alarm: In order to protect the battery and ensure infusion safety, there are different levels of acousto-optic prompts when the electric quantity of the battery is changing from close to depletion to almost depleted.

7.Move: When user tries to remove or take away the syringe, give move alarm.

8. High Flow Safety Confirm: In order to ensure infusion safety, when the flow rate is greater than 300ml/h (or equivalent), the device will prompt user to confirm again, and will not carry out infusion before confirmation.

9. Bubble Alarm: A continuously large number of bubbles going into the human body can form the air embolus, and it is life-threatening. So when bubble length is about 3mm (10.6ul) or accumulated bubble length is about 3mm (10.6ul) is detected, will trigger acoustic-optic alarm.

10. Drip Sensor Slope: In d/min mode, when there are problems such as tube slope, liquid overflow and misplaced/moved sensor, there will be an alarm.